The following operating systems are supported by Oneac. The pseudo-sine wave UPS systems do not have the interface board supplied with them so a kit with the board included will be required. The pure sine wave UPS systems come with the interface board already installed. Each of the model numbers shown in the body of the following table must be preceded by an appropriate suffix from the top of the table for a complete model number. Contact your Gryphon representative for help with your specific application.

OPERATING SYSTEMS SUPPORTEDPC CARD+ SOFTWARE+ CABLESOFTWARE+ CABLEPC CARD+ CABLECABLE ONLY
Model Suffix:AK-SK-IK-CK-
NETWARE 3.x & 4.1
BasicNovMopNovMop  
AdvancedNovMop+NovMop+  
Remote ManagementNovMop/RMNovMop/RM  
Multiple Server Control   OnePlus
UPS NLM provided w/ NETWARE
Serial Mouseport   Nov/PS2M
With an existing UPS monitoring board   Nov/DCB
Parallel Port  UPSMon 
UNIX
AIX(IBM)AIXMopUnixMop  
DG/UX (Data General)DGMopDGMop  
Digital Unix (DEC)DECMopUnixMop  
HP-UX for PA-RISC (Hewlett Packard)HPUXMopUnixMop  
Model Suffix:AK-SK-IK-CK-
IRIX (Silicon Graphics)SGIMopUnixMop  
MP-RAS (NCR)MPRASUnixMop  
SCO UNIX (Intel)SCOMopUnixMop  
Solaris 2.x, SPARC (Sun)SolMopUnixMop  
Sv/88 (Motorola)MotMop (4mm)UnixMop  
SunOS 4.13 Solaris 1.x SPARC (Sun)SunMopUnixMop  
UnixWareUWareMopUnixMop  
Multiple Server Control   OnePlus
OTHER OPERATING SYSTEMS
OS/2OS2MopOS2Mop  
Windows NT WinNTMop WinNT
Windows 95/98 WinNTMop WinNT
Multiple Servers   OnePlus
Banyan Vines   Banyan
AS/400   AS400B
SNMP InterfaceSNMP-NE   
Nortel   NTMeridian
Remote Control Modem & SoftwareOneRemote**   
Model Suffix:AK-SK-IK-CK-

**Oneac has 2 versions of the UPS Parameter Control software: the SW-ChgUPS for on-site manipulation of the UPS operating parameters; and the SW-ChgUPS/R for remote control of the UPS operating parameters through an appropriate modem.


The following specifications are dependent upon the level of software chosen and the basic capabilities of the operating system.

SOFTWARE SPECIFICATIONSNOVELL NETWAREUNIXOS/2 &
LAN
SERVER
WINDOWS
9x, NT &
BANYAN
SNMP
BASICADVANCEDREMOTE
MGMT.
AUTOMATED POWER FAIL RESPONSE
Automatic system shutdownXXXXXX 
Automatic system rebootXXXXXXX
Multiple server shutdown/reboot XXX X 
Administrative/user alertsXXXXXXX
Customizable shutdown scriptXXXXXX 
UPS battery conservation modeXXXXXX 
UPS & AC LINE STATUS INFORMATION
Report results of UPS self-tests XXXX X
Service/maintenance alerts XXXX X
Battery replacement warning XXXX X
UPS status information XXXX X
UPS & power event logging XXXX X**
REMOTE MANAGEMENT
Remote control via workstation  X   X
Real-time paging alerts XXXX X
Real-time e-mail alerts   X   
SNMP      X
SOFTWARE SPECIFICATIONSBASICADVANCEDREMOTE