Gryphon, Inc.

Oneac Home Icon Email Icon

ONEAC THREE PHASE, 50/60 Hertz PRODUCTS

All products come in a variety of plug and receptacle configurations. Contact your Gryphon representative for help with your specific application.

MODELINPUT VOLTAGEOUTPUT VOLTAGEOUTPUT RATINGLOAD RATINGDOWNLOAD
SPEC SHEETS
CRM Series
Rack Mount
208-480v
tap range
208/120v wye5.8-8.3kva16-23a/Ø 
CSD Series190-480v
tap range
208/120v wye5.76-19.8kva16-55a/Ø 
CDR Series190-480v
tap range
208/120v wye7.2-10.8kva20-30a/Ø 
CDR Series190-480v
tap range
208/120v wye20-45kva55-125a/Ø 
CLD Series190-480v
tap range
208/120v wye54-100kva150-278a/ØPDF Icon
CD Series190-600v
tap range
208/120v wye21.6-100kva60-278a/ØPDF Icon
FA Series190-600v
tap range
173-600v
tap range
 30-60a/ØPDF Icon
FA Series190-600v
tap range
173-600v
tap range
 100-200a/ØPDF Icon


Home
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CRM Series, Rack Mount
TYPE:Three Phase, 50/60 Hertz
INPUT:208-480V Delta Tap Range
OUTPUT:208/120 Wye
RATINGS:5.8-8.3kVA
16-23A/Ø

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be easily changed by user selection of the appropriate multi-pin jumper plug and input circuit breaker plug. Contact your Gryphon representative for help with your specific application.

MODELCRM06ICRM07ICRM08I
Output Rating (kVA)5.87.28.3
Load Current Rating (Amps)16/Ø20/Ø23/Ø
Input Voltage (VAC) (Delta)208,240,380,
415,480
208,240,380,
415,480
208,240,380,
415,480
Output Voltage (VAC) (Wye)208/120208/120208/120
Input Over Current Protection30A 600V rated circuit breaker frames with modular rating plug and auxiliary undervoltage release incorporated
MODELCRM06ICRM07ICRM08I
1kHz Forward Transfer Impedance (Ohms)<1.5<1.5<1.5
Heat Loss @ 80% Load (BTU/Hr.)<650<775<875
Agency ApprovalsUL & cUL, CE EN60950 & 50082,
IEC1000-2, -3, & -4
Width19" rackmont
Height8.75" (5U)
Depth (Inches)202020
Shipping Weight (Lbs.)190210210
MODELCRM60ICRM70ICRM80I


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CSD Series
TYPE:Three Phase, 50/60 Hertz
INPUT:190-480V Delta Tap Range
OUTPUT:208/120 Wye
RATINGS:5.76-19.8kVA
16-55A/Ø

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCSD31060CSD31100CSD31150CSD31200
Output Rating (kVA)5.7610.814.419.8
Load Current Rating (Amps)16/Ø30/Ø40/Ø55/Ø
Input Voltage (VAC) (Delta)190,208,240 or 208 or 380,400,480200,208,220, 230,240 or
208 or 480
200,208,220, 230,240 or
208
200,208,220, 230,240
Output Voltage (VAC) (Wye)208/120208/120208/120208/120
Load Regulation (RMS)±2%±2%±2%±2%
Inrush - ½ cycle (Amps)300450520715
Surge Current (Amps) 1 sec. typical110171248348
MODELCSD31060CSD31100CSD31150CSD31200
Surge Current (Amps) 5 sec. typical3990128176
1kHz Forward Transfer Impedance (Ohms)<1.9<1<1<1
Efficiency (%)>97>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)<600<700<700<1550
Agency ApprovalsUL1012 & CSA C22.2 No. 66
Width (Inches)11.46171717
Height (Inches)10.53232323
Depth (Inches)22.66262626
Shipping Weight (Lbs.)200340370385
MODELCSD31060CSD31100CSD31150CSD31200


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CDR Series
TYPE:Three Phase, 50/60 Hertz
INPUT:190-480V Delta Tap Range
OUTPUT:208/120 Wye
RATINGS:7.2-10.8kVA
20-30A/Ø

These products come with a variety of input and output options. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCDR07I-CDR08I-CDR10I-
Output Rating (kVA)7.28.610.8
Load Current Rating (Amps)20/Ø24/Ø30/Ø
Input Voltage (VAC) (Delta)190,200,208,
240,380,400,
408,415,420,
448,480
190,200,208,
240,380,400,
408,415,420,
448,480
190,200,208,
240,380,400,
408,415,420,
448,480
Output Voltage (VAC) (Wye)208/120208/120208/120
1kHz Forward Transfer Impedance (Ohms)<1.5<1.5<1.5
Efficiency (%)>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)<700<800<1100
MODELCDR07ICDR08ICDR10I
Input Breakerfor low & high input voltage
Emergency Mains Offoptional standard or fail-safe versions
Output Distributionterminal block
or
up to 2 3-gang IEC320 panels
Convenience Circuitsoptional combination of duplexs, twist locks, and IEC connectors
Indicators & ControlsPower On LED, Power Available LED
Agency ApprovalsUL, cUL, CE, SEMI S-2
Coolingconvectionconvectionconvection
Footprint (Square Inches)238238238
Width (Inches)141414
Height (Inches)24.524.524.5
Depth (Inches)161616
Shipping Weight (Lbs.)300300300
MODELCDR07I-CDR08I-CDR10I-


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CDR Series
TYPE:Three Phase, 50/60 Hertz
INPUT:190-480V Delta Tap Range
OUTPUT:208/120 Wye
RATINGS:20-45kVA
55-125A/Ø

These products come with a variety of input and output options. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCDR20I-CDR36I-CDR45I-
Output Rating (kVA)203645
Load Current Rating (Amps)55/Ø100/Ø125/Ø
Input Voltage (VAC) (Delta)190,200,208,
240,380,400,
408,415,420,
448,480
190,200,208,
240,380,400,
408,415,420,
448,480
200,208,240,
380,400,415,
480
Output Voltage (VAC) (Wye)208/120208/120208/120
1kHz Forward Transfer Impedance (Ohms)<0.9<0.7<0.25
Efficiency (%)>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)232536004550
CDR08ICDR20I-CDR36I-CDR45I-
Input Breakerfor low & high input voltage, with & without under/over voltage control
optional universal breaker on CDR451- only
Emergency Mains Offoptional standard or fail-safe versions
Output Distributionoptional terminal block & up to 3 30-pole 3Ø panels
Convenience Circuitsoptional combination of duplexs, twist locks, and IEC connectors
Indicators & Controlsoptional combinations of LED indicators and output control contactors
Agency ApprovalsUL, CSA, CE, GS/TUV, SEMI S-2
Coolingfan assistedfan assistedfan assisted
Footprint (Square Inches)445445445
Width (Inches)21.7521.7521.75
Height (Inches)62.7162.7162.71
Depth (Inches)20.520.520.5
Shipping Weight (Lbs.)400650750
MODELCDR20I-CDR36I-CDR45I-


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CLD SeriesPDF Icon Download Spec Sheets
TYPE:Three Phase, 50/60 Hertz
INPUT:190-480V Delta Tap Range 
OUTPUT:208/120 Wye 
RATINGS:54-100kVA 
150-278A/Ø 

These products are all hardwired input and output. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCLD31500CLD31750CLD31810CLD311000
Output Rating (kVA)547281100
Load Current Rating (Amps)150/Ø200/Ø225/Ø278/Ø
Input Voltage (VAC) (Delta)190,208,240 or 380,400,480380,400,480380,400,480380,400,480
Output Voltage (VAC) (Wye)208/120 or 415/240208/120 or
415/240
208/120 or 415/240208/120 or 415/240
1kHz Forward Transfer Impedance (Ohms)<0.25<0.2<0.2<0.2
Efficiency (%)>98>98>98>98
MODELCLD31500CLD31750CLD31810CLD311000
Heat Loss @ 80% Load (BTU/Hr.)<3688<4918<5200<5800
Agency ApprovalsUL1012 & IEC 380
Width (Inches)30.630.630.630.6
Height (Inches)50.550.550.550.5
Depth (Inches)32.632.632.632.6
Shipping Weight (Lbs.)1080145514551805
MODELCLD31500CLD31750CLD31810CLD311000


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CD SeriesPDF Icon Download Spec Sheets
TYPE:Three Phase, 50/60 Hertz
INPUT:190-600V Delta Tap Range 
OUTPUT:208/120 Wye 
RATINGS:21.6-100kVA 
60-278A/Ø 

These products are all hardwired input and output. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCD31200CD31300CD31500CD31750CD31810CD311000
Output Rating (kVA)21.628.8547281100
Load Current Rating (Amps)60/Ø80/Ø150/Ø200/Ø225/Ø278/Ø
Input Voltage (VAC) (Delta)190,200, 208,220, 230,240
or
380,390, 400,415, 440,460, 480
190,200, 208,220, 230,240
or
380,390, 400,415, 440,460, 480
190,200, 208,220, 230,240
or
380,390, 400,415, 440,460, 480 or 600
190,200, 208,220, 230,240
or
380,390, 400,415, 440,460, 480
380,390, 400,415, 440,460, 480480,600
Output Voltage (VAC) (Wye)208/120
or
415/240
208/120
or
415/240
208/120
or
415/240
208/120
or
415/240
208/120
or
415/240
208/120
or
415/240
MODELCD31200CD31300CD31500CD31750CD31810CD311000
1kHz Forward Transfer Impedance (Ohms)<0.6<0.5<0.25<0.2<0.2<0.2
Efficiency (%)>98>98>98>98>98>98
Heat Loss @ 80% Load (BTU/Hr.)<1475<1967<3688<4918<5200<5800
Agency ApprovalsUL1012; CSA 22.2 No. 66; IEC380
Width (Inches)272730.530.530.530.5
Height (Inches)48.548.568686868
Depth (Inches)222236363636
Shipping Weight (Lbs.)8659651250155015501900
MODELCD31200CD31300CD31500CD31750CD31810CD311000


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:FA SeriesPDF Icon Download Spec Sheets
TYPE:Three Phase, 50/60 Hertz
INPUT:190-600V Delta or Wye Tap Range 
OUTPUT:190-600V Delta or Wye Tap Range 
RATINGS:30-60A/Ø 

These products are all hardwired input and output. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELFA23030FA63030FA23060FA63060
Load Current Rating (Amps)30/Ø30/Ø60/Ø60/Ø
Input Voltage (VAC) (Wye)173/100 to 250/144173/100 to 600/346173/100 to 250/144173/100 to 600/346
Input Voltage (VAC) (Delta)173 to 250173 to 600173 to 250173 to 600
Output Voltage (VAC) (Wye)173/100 to 250/144173/100 to 600/346173/100 to 250/144173/100 to 600/346
Output Voltage (VAC) (Delta)173 to 250173 to 600173 to 250173 to 600
Surge Current (Amps) 10 sec. typical150150300300
MODELFA23030FA63030FA23060FA63060
1kHz Forward Transfer Impedance (Ohms)<1<1<1<1
Noise Rejection
NM & CM (Volts)
<20<20<20<20
Efficiency (%)>98>98>98>98
Agency ApprovalsUL & CSA
EnclosureNEMA12NEMA12NEMA12NEMA12
Width (Inches)16162020
Height (Inches)24243030
Depth (Inches)9999
Shipping Weight (Lbs.)8585150150
MODELFA23030FA63030FA23060FA63060


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:FA SeriesPDF Icon Download Spec Sheets
TYPE:Three Phase, 50/60 Hertz
INPUT:190-600V Delta or Wye Tap Range 
OUTPUT:190-600V Delta or Wye Tap Range 
RATINGS:100 - 200A/Ø 

These products are all hardwired input and output. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELFA23100FA63100FA23200FA43200FA63200
Load Current Rating (Amps)100/Ø100/Ø200/Ø200/Ø200/Ø
Input Voltage (VAC) (Wye)173/100 to 250/144173/100 to 600/346173/100 to 250/144173/100 to 480/277173/100 to 600/346
Input Voltage (VAC) (Delta)173 to 250173 to 600173 to 250173 to 480173 to 600
Output Voltage (VAC) (Wye)173/100 to 250/144173/100 to 600/346173/100 to 250/144173/100 to 480/277173/100 to 600/346
Output Voltage (VAC) (Delta)173 to 250173 to 600173 to 250173 to 480173 to 600
Surge Current (Amps) 10 sec. Typical500500100010001000
1kHz Forward Transfer Impedance (Ohms)<1<1<1<1<1
MODELFA23100FA63100FA23200FA43200FA63200
Noise Rejection NM & CM (Volts)<20<20<20<20<20
Efficiency (%)>98>98>98>98>98
Agency ApprovalsUL & CSA
EnclosureNEMA12NEMA12NEMA12NEMA2NEMA2
Width (Inches)2424303030
Height (Inches)3030364141
Depth (Inches)1313171717
Shipping Weight (Lbs.)210210365455455
MODELFA23100FA63100FA23200FA43200FA63200


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index