MODELINPUT VOLTAGEOUTPUT VOLTAGEOUTPUT RATINGLOAD RATINGDOWNLOAD
SPEC SHEETS
CSD Series190-240v
tap range
240v,
120/240 split Ø
8-9.6kva66.7-80a@120v 33.3-40a@240v 
CMK SeriesEuropean versions with plugs & receptacles appropriate to each specific countryPDF Icon
200-250v
tap range
200-250v
tap range
125va-2kva.5-8a
BBC SeriesEuropean versions with IEC320 plugs & connectorsPDF Icon
200-250v
tap range
200-250v
tap range
150va-1.7kva.6-6.8a
CBS Series110-240v
tap range
114-240v
tap range
1.92kva16a@120v
8a@240v
 
FMV SeriesNo cabinet (used as built-in) 
100-240v
tap range
120v,240v550va-2.16kva4.6-18a@120v 2.3-6a@240v
CCS Series100-240v
tap range
114-240v
tap range
2.88kva24a@120v 12a@240v 
CCS Series110-240v
tap range
114-240v
tap range
4.8kva40a@120v 20a@240v 
CX SeriesNEMA cabinet version and plate version w/o cabinet (used as built-in)PDF IconNEMA
PDF Icon Plate
120,240,480v 120/240 split Ø 240va-1kva1.2-8.3a@120v .6-4.2a@240v
MODELINPUT VOLTAGEOUTPUT VOLTAGEOUTPUT RATINGLOAD RATINGDOWNLOAD
SPEC SHEETS


Home
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: CSD Series
TYPE: Single Phase, 50/60 Hertz
INPUT: 190-240V Tap Range
OUTPUT: 240V, 120/240 split Ø
RATINGS: 8-9.6kVA
66.7-80A@120V, 33.3-40A@240V

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCSD2280CSD22100CSD2380CSD23100
Output Rating (kVA)89.689.6
Load Current Rating @ 120/240v (Amps)66.7/33.34066.7/33.380/40
Input Voltage (VAC)200,208,225, 240200,208,220, 230,240200,208,225, 240200,208,220, 230,240
Output Voltage (VAC)120/240 split Ø240120/240 split Ø120/240 split Ø
Load Regulation (RMS)±2%±2%±2%±2%
Inrush - ½ Cycle (Amps)450520450520
Surge Current (Amps@120v)
1 sec. typical
210248210248
MODELCSD2280CSD22100CSD2380CSD23100
Surge Current (Amps@120v)
5 sec. typical
100128100128
1kHz Forward Transfer Impedance (Ohms)<2<2<2<2
Efficiency (%)>97>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)<550<700<550<700
Agency ApprovalsUL1012 CSA C22.2 No. 107.1
Line Cord (Feet)Hard WiredYesHard WiredYes
Width (Inches)17171717
Height (Inches)23232323
Depth (Inches)26262626
Shipping Weight (Lbs.)390345390345
MODELCSD2280CSD22100CSD2380CSD23100


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: CMK SeriesEuropean ModelsPDF Icon Download Spec Sheets
TYPE: Single Phase, 50/60 Hertz
INPUT: 200-250V Tap Range 
OUTPUT: 200-250V Tap Range 
RATINGS: 125VA-2kVA 
0.5-8A@250V 

These products come in a variety of plug and receptacle configurations depending on the requirements of the specific European country where they will be installed. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCMK2201CMK2202CMK2205CMK2207CMK2210CMK2215CMK2220
Output Rating @250v (VA)125250500750100015002000
Load Current Rating (Amps)0.5123468
Input Voltage (VAC)
Tap Range
200-250200-250200-250200-250200-250200-250200-250
Output Voltage (VAC)
Tap Range
200-250200-250200-250200-250200-250200-250200-250
Load Regulation (RMS)±4%±3%±2.5%±2%±2%±1.5%±1.5%
Inrush - ½ Cycle (Amps)81530456090120
MODELCMK2201CMK2202CMK2205CMK2207CMK2210CMK2215CMK2220
Surge Current (Amps)
1 sec. typical
651015203040
Surge Current (Amps)
5 sec. typical
42.557.5101520
Output Current Crest Factor for <10% Drop in Peak Voltage2.5333355
1kHz Forward Transfer Impedance (Ohms)<70<50<25<16<13<7<4.5
MODELCMK2201CMK2202CMK2205CMK2207CMK2210CMK2215CMK2220
Efficiency (%)>90>92>93>94>95>96>96
Heat Loss @ 80% Load (BTU/Hr.)<40<50<80<105<120<165<235
Agency ApprovalsBS5850 (UK only), BS7702, VDE0805, EN 60 950 (except SWISS)
Plug/Receptacle TypeVarious depending on the specific European Country
Number of Receptacles1334455
Width (mm)66248248314314377377
Height (mm)127136136170170202202
Depth (mm)173225225275275290290
Shipping Weight (kg)481014162430
MODELCMK2201CMK2202CMK2205CMK2207CMK2210CMK2215CMK2220


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: BBC SeriesEuropean ModelsPDF Icon Download Spec Sheets
TYPE: Single Phase, 50/60 Hertz
INPUT: 200-250V Tap Range 
OUTPUT: 200-250V Tap Range 
RATINGS: 150VA-1.7kVA 
0.6-6.8A@250V  

These products only come with IEC320 plugs and connectors. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELBBC150BBC250BBC375BBC575BBC1000BBC1700
Output Rating @250v (VA)15025037557510001700
Load Current Rating (Amps)0.611.52.346.8
Input Voltage
(VAC) Tap Range
200-250200-250200-250200-250200-250200-250
Output Voltage (VAC) Tap Range200-250200-250200-250200-250200-250200-250
Load Regulation (%)±2.5±2.5+2.5/-4.0+2.5/-3.0±2.5±2.0
Inrush - ½ Cycle (Amps)81215304590
Surge Current (Amps) 1 sec. typical655101530
MODELBBC150BBC250BBC375BBC575BBC1000BBC1700
Surge Current (Amps) 5 sec. typical42.52.557.515
Output Current Crest Factor for <10% Drop in Peak Voltage2.533335
1kHz Forward Transfer Impedance (Ohms)<90<65<60<25<14<8
Efficiency (%)>90>90>90>93>93>93
Heat Loss @ 80% Load (BTU/Hr.)<50<75<105<139<180<325
Earth Leakage (typical)<100µA<100µA<100µA<100µA<100µA<100µA
MODELBBC150BBC250BBC375BBC575BBC1000BBC1700
Operating Temperature (°C)-20 to +35-20 to +35-20 to +35-20 to +35-20 to +35-20 to +35
Plug/Receptacle TypeIEC320IEC320IEC320IEC320IEC320IEC320
Number of Output Connectors133345
Output Leads Supplied111122
Width (mm)124187187187202237
Height (mm)100124124124149184
Depth (mm)183259259259284334
Shipping Weight (kg)5.288.410.414.423.1
MODELBBC150BBC250BBC375BBC575BBC1000BBC1700


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: CBS Series
TYPE: Single Phase, 50/60 Hertz
INPUT: 110-240V Tap Range
OUTPUT: 114-240V Tap Range
RATINGS: 1.92kVA
16A@120V, 8A@240V

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCBS1120CBS2120CBS2220CBS2320
Output Rating (kVA)1.921.921.921.92
Load Current Rating (Amps)16@120v16@120v8@240v16@120v 8@240v
Input Voltage (VAC)100,108,120200,208,216, 220,228,240200,208,216, 220,228,240200,208,216, 220,228,240
Output Voltage (VAC)114,120114,120228,240114/228 split Ø, 120/240 split Ø
Load Regulation (RMS)±2%±2%±2%±2%
Inrush - ½ Cycle (Amps)400150150150
Surge Current (Amps@120v)
1 sec. typical
80555555
MODELCBS1120CBS2120CBS2220CBS2320
Surge Current (Amps@120v)
5 sec. typical
42191919
1kHz Forward Transfer Impedance (Ohms)<7.9<7.6<7.6<7.6
Efficiency (%)>95>95>95>95
Heat Loss @ 80% Load (BTU/Hr.)<200<200<200<200
Agency ApprovalsUL1012 CSA C22.2 No. 66
Line Cord (Feet)10101010
Width (Inches)9.59.510.510.5
Height (Inches)8810.510.5
Depth (Inches)151517.617.6
Shipping Weight (Lbs.)717197119
MODELCBS1120CBS2120CBS2220CBS2320


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: FMV SeriesBuilt-In Models
TYPE: Single Phase, 50/60 Hertz
INPUT: 100-240V Tap Range
OUTPUT: 120V, 240V
RATINGS: 550VA-2.16kVA
4.6-18A@120V, 2.3-6A@240V

All products come with a terminal strip for voltage connections. These units are specifically for built-in applications and hence come without any cabinet. Contact your Gryphon representative for help with your specific application.

MODELFMV3205FMV3210FMV3215FMV3220
Output Rating (VA)550100014402160
Load Current Rating (Amps) 120/240v4.6/2.38.4/4.212/618@120v
Input Voltage (VAC) Tap Range100-240100-240100-240190-240
Output Voltage (VAC)120,240120,240120,240120
Load Regulation (RMS)±3.5%±3.5%±2%±2%
1kHz Forward Transfer Impedance (Ohms)<6@120v <30@240v<3.6@120v <15@240v<3.6@120v <15@240v<2.6@120v
MODELFMV3205FMV3210FMV3215FMV3220
Leakage Current (µA)<100<100<100<100
Agency ApprovalsUL544,UL1012; CSA C22.2 No. 66; IEC 601-1; VDE 0750 FMV3220 only: UL1262
Width
(Inches {cm})
5.375 {13.65}5.375 {13.65}6.375 {16.2}11.25 {28.58}
Height
(Inches {cm})
4.5 {11.43}4.5 {11.43}5.31 {13.5}8.5 {21.6}
Depth
(Inches {cm})
7 {17.78}8 {20.32}9.5 {24.1}6.75 {17.15}
Shipping Weight
(Lbs.{kg})
20 {9.1}27 {12.5}40 {18.1}55 {25}
MODELFMV3205FMV3210FMV3215FMV3220


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: CCS Series
TYPE: Single Phase, 50/60 Hertz
INPUT: 110-240V Tap Range
OUTPUT: 114-240V Tap Range
RATINGS: 2.88kVA
24A@120V, 12A@240V

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCCS1128CCS2128CCS2228CCS2328
Output Rating (kVA)2.882.882.882.88
Load Current Rating (Amps)24@120v24@120v12@240v24@120v 12@240v
Input Voltage (VAC)100,108,120200,208,216, 220,228,240200,208,216, 220,228,240200,208,216, 220,228,240
Output Voltage (VAC)114,120114,120228,240114/228 split Ø, 120/240 split Ø
Load Regulation (RMS)±2%±2%±2%±2%
Inrush - ½ Cycle (Amps)500400400400
Surge Current (Amps) 1 sec. typical170808080
MODELCCS1128CCS2128CCS2228CCS2328
Surge Current (Amps) 5 sec. typical60424242
1kHz Forward Transfer Impedance (Ohms)<1.25<5<5<5
Efficiency (%)>97>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)<250<250<250<250
Agency ApprovalsUL1012; CSA C22.2 No. 66
Line Cord (Feet)10101010
Width (Inches)10.510.510.510.5
Height (Inches)10.510.510.510.5
Depth (Inches)17.617.617.617.6
Shipping Weight (Lbs.)93969696
MODELCCS1128CCS2128CCS2228CCS2328


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS: CCS Series
TYPE: Single Phase, 50/60 Hertz
INPUT: 110-240V Tap Range
OUTPUT: 114-240V Tap Range
RATINGS: 4.8kVA
40A@120V, 20A@240V

These products come in a variety of plug and receptacle configurations. The specific voltage tap required can be pre-set at the factory. Contact your Gryphon representative for help with your specific application.

MODELCCS1148CCS2148CCS2248CCS2348
Output Rating (kVA)4.84.84.84.8
Load Current Rating (Amps)40@120v40@120v20@240v40@120v 20@240v
Input Voltage (VAC)100,108,120200,208,216, 220,228,240200,208,216, 220,228,240200,208,216, 220,228,240
Output Voltage (VAC)114,120114,120228,240114/228 split Ø, 120/240 split Ø
Load Regulation (RMS)±2%±2%±2%±2%
Inrush - ½ Cycle (Amps)720500500500
Surge Current (Amps) 1 sec. typical260170170170
MODELCCS1148CCS2148CCS2248CCS2348
Surge Current (Amps) 5 sec. typical92606060
1kHz Forward Transfer Impedance (Ohms)<.75<3<3<3
Efficiency (%)>97>97>97>97
Heat Loss @ 80% Load (BTU/Hr.)<410<410<410<410
Agency ApprovalsUL1012; CSA C22.2 No. 66
Line Cord (Feet)10101010
Width (Inches)10.510.510.510.5
Height (Inches)10.510.510.510.5
Depth (Inches)17.617.617.617.6
Shipping Weight (Lbs.)115115115115
MODELCCS1148CCS2148CCS2248CCS2348


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index

MODELS:CX SeriesNEMA Cabinet Version
Build-In Plate Version
PDF Icon Download NEMA Specs
PDF Icon Download Plate Specs
TYPE:Single Phase, 50/60 Hertz
INPUT:120V, 240V, 480V 
OUTPUT:120-240 split Ø  
RATINGS:240VA-1kVA 
1.2-8.3A@120V, 0.6-4.2A@240V 

All products come with a terminal strip for voltage connections. The "-P" plate version leaves the circuitry and parts exposed. The cabinet version (no Suffix) is identical to the plate version in every way with the exception of having the parts protected. Models CX500, CX750, and CX1000 each have a "N" version which has a NEMA 1 rated enclosure. The NEMA enclosure measures HxWxD 12"x12"x6" and adds 26 lbs. to the shipping weight. Contact your Gryphon representative for help with your specific application.

MODELCX140CX250CX500CX750CX1000
Output Rating (VA)1402505007501000
Load Current Rating (Amps) @ 120/240v1.2/0.62.0/1.04.2/2.16.25/3.18.3/4.2
Input Voltage (VAC)120,240,480120,240,480120,240,480120,240,480120,240,480
Output Voltage (VAC)120/240
split Ø
120/240
split Ø
120/240
split Ø
120/240
split Ø
120/240
split Ø
MODELCX140CX250CX500CX750CX1000
1kHz Forward Transfer Impedance (Ohms)<25@120v <100@240v<18@120v <72@240v<13@120v <52@240v<8@120v <32@240v<5@120v <20@240v
Efficiency (%)>90>90>90>97>97
Heat Loss @ 80% Load (BTU/Hr.)<30<43<68<90<110
Agency ApprovalsUL1012, UL 478; CSA C22.2 No. 66
Shipping Weight
(Lbs. {kg})
14 {6.36}17 {7.73}23 {10.45}33 {15}43 {19.54}
MODELCX140CX250CX500CX750CX1000
PLATE VERSION
Width
(Inches {cm})
4.74 {12.04}5.49 {13.94}5.82 {14.78}6.79 {17.25}6.71 {17.04}
Height
(Inches {cm})
3.2 {8.13}3.81 {9.68}3.81 {9.68}4.32 {10.97}4.32 {10.97}
Depth
(Inches {cm})
6.64 {16.87}6.64 {16.87}8.26 {20.98}9.51 {24.15}10.91 {27.71}
CABINET VERSION
Width
(Inches {cm})
7.82 {19.86}7.82 {19.86}7.82 {19.86}9.4 {23.88}9.4 {23.88}
Height
(Inches {cm})
5.06 {12.85}5.06 {12.85}5.06 {12.85}5.72 {14.53}5.72 {14.53}
Depth
(Inches {cm})
11.06 {28.09}11.06 {28.09}11.06 {28.09}13.8 {35.05}13.8 {35.05}
MODELCX140CX250CX500CX750CX1000


Home
Page

Top of
Page


60 Hz


50/60 Hz

Terms Defined

Model
Index